Airborne Mid-Infrared Cavity enhanced Absorption spectrometer (AMICA)

Vicheith Tan
  • Fonction : Auteur
J Brian Leen
  • Fonction : Auteur
Aaron Gardner
  • Fonction : Auteur
Xu Du
  • Fonction : Auteur
Thomas Kulessa
  • Fonction : Auteur
Johannes Schillings
  • Fonction : Auteur
Herbert Schneider
  • Fonction : Auteur
Stefanie Schrade
  • Fonction : Auteur
Chenxi Qiu
  • Fonction : Auteur
Marc von Hobe
  • Fonction : Auteur
  • PersonId : 850640

Résumé

We describe the Airborne Mid-Infrared Cavity enhanced Absorption spectrometer (AMICA) designed to measure trace gases in situ on research aircraft using Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS). AMICA contains two largely independent and exchangeable OA-ICOS arrangements, allowing for the simultaneous measurement of multiple substances in different infrared wavelength windows tailored to scientific questions related to a particular flight mission. Three OA-ICOS setups have been implemented with the aim to measure OCS, CO2, CO, and H2O at 2050 cm−1; O3, NH3, and CO2 at 1034 cm−1; and HCN, C2H2, and N2O at 3331 cm−1. The 2050 cm−1 setup has been characterized in the laboratory and successfully used for atmospheric measurements during two campaigns with the research aircraft M55 Geophysica and one with the German HALO (High Altitude and Long Range Research Aircraft). For OCS and CO, data for scientific use have been produced with 5 % accuracy (15 % for CO below 60 ppb, due to additional uncertainties introduced by dilution of the standard) at typical atmospheric mixing ratios and laboratory-measured 1σ precision of 30 ppt for OCS and 3 ppb for CO at 0.5 Hz time resolution. For CO2, high absorption at atmospheric mixing ratios leads to saturation effects that limit sensitivity and complicate the spectral analysis, resulting in too large uncertainties for scientific use. For H2O, absorption is too weak to be measured at mixing ratios below 100 ppm. By further reducing electrical noise and improving the treatment of the baseline in the spectral retrieval, we hope to improve precision for OCS and CO, resolve the issues inhibiting useful CO2 measurements, and lower the detection limit for H2O. The 1035 and 3331 cm−1 arrangements have only partially been characterized and are still in development. Although both setups have been flown and recorded infrared spectra during field campaigns, no data for scientific use have yet been produced due to unresolved deviations of the retrieved mixing ratios to known standards (O3) or insufficient sensitivity (NH3, HCN, C2H2, N2O). The ∼100 kg instrument with a typical in-flight power consumption of about 500 VA is dimensioned to fit into one 19 in. rack typically used for deployment inside the aircraft cabin. Its rugged design and a pressurized and temperature-stabilized compartment containing the sensitive optical and electronic hardware also allow for deployment in payload bays outside the pressurized cabin even at high altitudes of 20 km. A sample flow system with two parallel proportional solenoid valves of different size orifices allows for precise regulation of cavity pressure over the wide range of inlet port pressures encountered between the ground and maximum flight altitudes. Sample flow of the order of 1 SLM (standard litre per minute) maintained by an exhaust-side pump limits the useful time resolution to about 2.5 s (corresponding to the average cavity flush time), equivalent to 500 m distance at a typical aircraft speed of 200 m s−1.
Fichier principal
Vignette du fichier
amt-14-5271-2021.pdf (5.8 Mo) Télécharger le fichier
Origine : Publication financée par une institution

Dates et versions

insu-03319786 , version 1 (13-08-2021)

Licence

Paternité

Identifiants

Citer

Corinna Kloss, Vicheith Tan, J Brian Leen, Garrett L Madsen, Aaron Gardner, et al.. Airborne Mid-Infrared Cavity enhanced Absorption spectrometer (AMICA). Atmospheric Measurement Techniques, 2021, 14, pp.5271 - 5297. ⟨10.5194/amt-14-5271-2021⟩. ⟨insu-03319786⟩
380 Consultations
94 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More