Determination of Zr isotopic ratios in zircons using laser-ablation multiple-collector inductively coupled-plasma mass-spectrometry - INSU - Institut national des sciences de l'Univers Accéder directement au contenu
Article Dans Une Revue Journal of Analytical Atomic Spectrometry Année : 2019

Determination of Zr isotopic ratios in zircons using laser-ablation multiple-collector inductively coupled-plasma mass-spectrometry

Résumé

This study presents the first high precision method to analyze stable Zr isotope ratios in zircons using laser ablation multiple collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS). Interference problems for in situ Zr isotope analysis were investigated in detail. The polyatomic interferences of (YH+)-Y-89-H-1 and doubly charged ion interference of Hf-180(++) did not influence the Zr isotope analysis. The addition of 8 ml min(-1) nitrogen to the central gas flow in LA-MC-ICP-MS was found to increase the sensitivity of Zr by a factor of 1.95. The analysis mode of small laser spot sizes (16-32 mu m) and low laser frequency (1 Hz) combined with a signal-smoothing device was used. Compared to that without the signal-smoothing device, the obtained analytical precision was improved by about 60.6 times by using the signal-smoothing device at the low laser frequency (1 Hz). The accuracy of the in situ method is validated by comparing the data to those of a well-established double spike solution method. Data for six international zircon standards and six additional natural zircons are given. The data are reported as standard delta notation as the permil deviation of the Zr-94/Zr-90 (delta Zr-94/90(GJ-1)) and Zr-96/Zr-90 (delta Zr-96/90(GJ-1)) ratios relative to the GJ-1 zircon standard. Typical intermediate precisions for delta Zr-94/90(GJ-1) and delta Zr-96/90(GJ-1) were 0.11 and 0.18 parts per thousand (2SD, standard deviation). The delta Zr-94/90(GJ-1) values for the four zircon reference materials (91500, Plesovice, Penglai and Mud Tank) determined by LA-MC-ICP-MS were in good agreement with those of double spiked solution measurements, confirming the accuracy of the in situ method. The zircon reference material FC1 showed the largest stable isotope fractionation of 4.93 parts per thousand for delta Zr-94/90(GJ-1). One natural zircon (08KQ02-1) with a complex history showed a significant delta Zr-94/90(GJ-1) isotope variation in the single grain. These results suggest that Zr isotopes are a potentially powerful geochemical tracer and that high spatial-resolution, in situ determination like by the LA-MC-ICP-MS method in this study is rather important to identify Zr isotope variation in single zircon grains.
Fichier non déposé

Dates et versions

insu-02915516 , version 1 (14-08-2020)

Identifiants

Citer

Wen Zhang, Zaicong Wang, Frédéric Moynier, Edward Inglis, Shengyu Tian, et al.. Determination of Zr isotopic ratios in zircons using laser-ablation multiple-collector inductively coupled-plasma mass-spectrometry. Journal of Analytical Atomic Spectrometry, 2019, 34 (9), pp.1800-1809. ⟨10.1039/c9ja00192a⟩. ⟨insu-02915516⟩
24 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More