. Avec-cette-méthode, exécution d'un bloc prend environ 1h30 mn, l'ensemble du protocole aboutissant à l'analyse de 3 échantillons par heure de fonctionnement de l'ICP-MS (hors durée de mise en route) Ces chiffres peuvent servir de base pour estimer les coûts propagés par échantillon analysé

S. Aries, M. Valladon, M. Polvé, and B. Dupré, A Routine Method for Oxide and Hydroxide Interference Corrections in ICP-MS Chemical Analysis of Environmental and Geological Samples, Geostandards and Geoanalytical Research, vol.12, issue.Special Issue, pp.19-31, 2000.
DOI : 10.1111/j.1751-908X.2000.tb00583.x

D. Ashley, Polyatomic interferences due to the presence of inorganic carbon in environmental samples in the determination of chromium at mass 52 by ICP-MS, Atomic Spectroscopy, vol.39, issue.5, pp.169-172, 1992.

H. Packard, The HP4500 Benchtop ICP-MS: a Leap Forward. Publication N° 5962- 8463EUS, imprimé aux USA Hewlett-Packard, HP4500: Guide des applications. Publication G1820-93009, imprimé en Allemagne, 1995.

I. Jarvis and K. E. Jarvis, Plasma spectrometry in the earth sciences: techniques, applications and future trends, Chemical Geology, vol.95, issue.1-2, pp.1-23, 1992.
DOI : 10.1016/0009-2541(92)90041-3

K. E. Jarvis, A. L. Gray, and R. S. Houk, Handbook of inductively coupled plasma mass spectrometry, Blackie Academic and Professional, p.380, 1992.
DOI : 10.1007/978-94-011-3046-2

K. Hu, S. Clemons, P. Houk, and R. S. , Inductive coupled plasma mass spectrometry with an enlarged sampling orifice and offset ion lens. I. Ion trajectories and detector performance, Journal of the American Society for Mass Spectrometry, vol.4, issue.1, pp.16-27, 1993.
DOI : 10.1016/1044-0305(93)85038-Y

K. Hu, S. Clemons, P. Houk, and R. S. , Inductively coupled plasma mass spectrometry with an enlarged sampling orifice and offset ion lens. II. Polyatomic ion interferences and matrix effects, Journal of the American Society for Mass Spectrometry, vol.4, issue.1, pp.28-37, 1993.
DOI : 10.1016/1044-0305(93)85039-Z

K. Falkner, K. Klinkhammer, G. P. Ungerer, C. A. Christie, and D. M. , Inductively Coupled Plasma Mass Spectrometry in Geochemistry, Annual Review of Earth and Planetary Sciences, vol.23, issue.1, pp.409-449, 1995.
DOI : 10.1146/annurev.ea.23.050195.002205

Y. Kishi and M. Matsuda, The determination of traces elements in drinking water by ICP-MS, ICP-MS Application Note 228-312, The HP 4500 Benchtop ICP-MS: a leap forward, 1994.

Y. Kishi and S. Nagaoka, The determination of traces elements in riverine water by ICP-MS, ICP-MS Application Note 228-314, The HP 4500 Benchtop ICP-MS: a leap forward, pp.5962-8463, 1994.

R. Christine, Géochimie des terres rares et des éléments traces associés dans les nappes et l'eau des sols hydromorphes, Thèse de doctorat de Géosciences de Rennes I, 1999.

D. T. Scott, P. Michael, S. A. Beres, and E. D. Denoyer, The application of cold plasma conditions for the determination of trace levels, Atomic Spectroscopy, pp.16-18, 1995.

A. Stroh, Analysis of rare earth elements in natural waters by ICP-MS, Atomic Spectroscopy, vol.13, issue.3, pp.89-92, 1992.

F. Vanhaecke, H. Vanhoe, and R. Dams, The use of internal standards in ICP-MS, Talanta, vol.39, issue.7, pp.39-737, 1992.
DOI : 10.1016/0039-9140(92)80088-U