Heat flux measurement from thermal infrared imagery in low-flux fumarolic zones: Example of the Ty fault (La Soufrière de Guadeloupe) - INSU - Institut national des sciences de l'Univers Accéder directement au contenu
Article Dans Une Revue Journal of Volcanology and Geothermal Research Année : 2013

Heat flux measurement from thermal infrared imagery in low-flux fumarolic zones: Example of the Ty fault (La Soufrière de Guadeloupe)

Résumé

Monitoring the geothermal flux of a dormant volcano is necessary both for hazard assessment and for studying hydrothermal systems. Heat from a magma body located at depth is transported by steam to the surface, where it is expelled in fumaroles if the heat flow exceeds 500 W/m2. If the heat flow is lower than 500 W/m2, steam mainly condensates in the soil close to surface and produces a thermal anomaly detectable at the surface. In this study, we propose a method to quantify low heat fluxes from temperature anomalies measured at the surface by a thermal infrared camera. Once corrected from the atmospheric and surface effects, thermal infrared images are used to compute (1) the excess of radiative flux, (2) the excess of sensible flux and (3) the steam flux from the soil to the atmosphere. These calculations require measurements of atmospheric parameters (temperature, wind velocity and humidity) and estimations of surface parameters (roughness and emissivity). This method has been tested on a low-flux fumarolic zone of the Soufrière volcano (Guadeloupe Island -- Lesser Antilles), and compared to a flux estimation realized from the thermal gradient measurements into the soil. The two methods show a good agreement and a similar precision (267 ± 46 W/m2 for the thermal infrared method, and 275 ± 50 W/m2 for the vertical temperature gradient method), if surface roughness is well calibrated.
Fichier principal
Vignette du fichier
Gaudin2013_hal.pdf (1.38 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

insu-00933596 , version 1 (03-11-2016)

Identifiants

Citer

Damien Gaudin, François Beauducel, Pascal Allemand, Christophe Delacourt, Anthony Finizola. Heat flux measurement from thermal infrared imagery in low-flux fumarolic zones: Example of the Ty fault (La Soufrière de Guadeloupe). Journal of Volcanology and Geothermal Research, 2013, 267, pp.47-56. ⟨10.1016/J.JVOLGEORES.2013.09.009⟩. ⟨insu-00933596⟩
336 Consultations
452 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More