Quantification of dissolved CO2 in silicate glasses using micro-Raman spectroscopy - INSU - Institut national des sciences de l'Univers Accéder directement au contenu
Article Dans Une Revue The American Mineralogist Année : 2013

Quantification of dissolved CO2 in silicate glasses using micro-Raman spectroscopy

Résumé

This study investigates the potential use of confocal micro-Raman spectroscopy for the quantification of CO2 in geologically relevant glass compositions. A calibration is developed using a wide range of both natural and synthetic glasses that have CO2 dissolved as carbonate (CO32−) in the concentration range from 0.2 to 16 wt%. Spectra were acquired in the 200 and 1350 cm−1 frequency region that includes the ν1 Raman active vibration for carbonate at 1062-1092 cm−1 and the intensity of this peak is compared to various other peaks representing the aluminosilicate glass structure. The most precise and accurate calibration is found when carbonate peaks are compared to aluminosilicate spectral features in the high-frequency region (HF: 700-1200 cm−1), which can be simulated with several Gaussian peaks, directly related to different structural species in the glass. In some samples the "dissolved" CO32− appears to have two different Raman bands, one sharper than the other. This may be consistent with previous suggestions that CO32− has several structural environments in the glass, and is not related to any precipitation of crystalline carbonate from the melt during quenching. The calibration derived using the HF peaks appears linear for both the full range of glass composition considered and the range of CO2 concentrations, even when multiple carbonate peaks are involved. We propose the following, compositionally independent linear equation to quantify the CO2 content in glass with micro-Raman spectroscopy Formula where CO3/HF is the area ratio of the fitted ν1 carbonate peak(s) at 1062-1092 cm−1 to the remaining area of the fitted aluminosilicate envelope from 700-1200 cm−1. This is similar to the Raman calibration developed for water, but is complicated by the overlapping of these two fitted components. Using error propagation, we propose the calibration accuracy is better than ±0.4 wt% CO2 for our data set. The ν1 Raman peak position for carbonate is not constant and appears to be correlated with the density of the melt (or glass) in some way rather than the chemical composition.
Fichier non déposé

Dates et versions

insu-00876085 , version 1 (23-10-2013)

Identifiants

Citer

Yann Morizet, Richard A. Brooker, Giada Iacono-Marziano, Bruce A. Kjarsgaard. Quantification of dissolved CO2 in silicate glasses using micro-Raman spectroscopy. The American Mineralogist, 2013, 98, pp.1788-1802. ⟨10.2138/am.2013.4516⟩. ⟨insu-00876085⟩
215 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More