R. W. Alkire, G. Rosenbaum, and G. Evans, Design of a vacuum-compatible high-precision monochromatic beam-position monitor for use with synchrotron radiation from 5 to 25???keV, Journal of Synchrotron Radiation, vol.7, issue.2, pp.61-68, 2000.
DOI : 10.1107/S090904959901568X

D. Bazin and J. J. Rehr, Limits and Advantages of X-ray Absorption Near Edge Structure for Nanometer Scale Metallic Clusters, The Journal of Physical Chemistry B, vol.107, issue.45, pp.12398-12402, 2003.
DOI : 10.1021/jp0223051

URL : https://hal.archives-ouvertes.fr/hal-00431063

D. H. Bilderback, The potential of cryogenic silicon and germanium X-ray monochromators for use with large synchrotron heat loads, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol.246, issue.1-3, pp.434-436, 1986.
DOI : 10.1016/0168-9002(86)90126-9

F. Bridges, A simple feedback system to keep the flux from an X-ray double monochromator constant, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol.257, issue.2, pp.447-450, 1987.
DOI : 10.1016/0168-9002(87)90772-8

P. Carpentier, M. Rossat, P. Charrault, J. Joly, M. Pirocchi et al., Synchrotron monochromator heating problem, cryogenic cooling solution, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol.456, issue.3, pp.163-176, 2001.
DOI : 10.1016/S0168-9002(00)00578-7

F. Comin, A cryogenically cooled, sagittal focusing scanning monochromator for ESRF, Review of Scientific Instruments, vol.66, issue.2, pp.2082-2084, 1995.
DOI : 10.1063/1.1145734

J. O. Cross, W. T. Elam, V. G. Harris, J. Kirkland, C. E. Bouldin et al., Sample-angle feedback for diffraction anomalous fine-structure spectroscopy, Journal of Synchrotron Radiation, vol.5, issue.3, pp.911-913, 1998.
DOI : 10.1107/S0909049597014313

R. J. Dejus and M. S. Del-rio, XOP: A graphical user interface for spectral calculations and x???ray optics utilities, Review of Scientific Instruments, vol.67, issue.9, p.3356, 1996.
DOI : 10.1063/1.1147376

E. M. Dufresne, D. A. Arms, S. B. Dierker, R. Clarke, Y. Yacoby et al., Design and performance of a stable first crystal mount for a cryogenically cooled Si monochromator at the Advanced Photon Source, Review of Scientific Instruments, vol.73, issue.3, pp.1511-1513, 2002.
DOI : 10.1063/1.1423630

J. L. Hazemann, K. Nayouf, and F. De-bergevin, Modelisation by finite elements of sagittal focusing, Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, vol.97, issue.1-4, pp.547-550, 1995.
DOI : 10.1016/0168-583X(94)00731-4

R. Hettel, Review of synchrotron beam stability and stabilizing systems (invited), Review of Scientific Instruments, vol.60, issue.7, pp.1501-1506, 1989.
DOI : 10.1063/1.1140970

P. R. Jemian, Software feedback for monochromator tuning at UNICAT (abstract), Review of Scientific Instruments, vol.73, issue.3, p.1533, 2002.
DOI : 10.1063/1.1448163

K. V. Klementev, Deconvolution problems in x-ray absorption fine structure spectroscopy, Journal of Physics D: Applied Physics, vol.34, issue.15, pp.2241-2247, 2001.
DOI : 10.1088/0022-3727/34/15/301

G. S. Knapp, C. S. Rogers, M. A. Beno, C. L. Wiley, G. Jennings et al., Cryogenic monochromator as a solution to undulator heat loads at third???generation synchrotron sources, Review of Scientific Instruments, vol.66, issue.2, pp.2138-2140, 1995.
DOI : 10.1063/1.1145752

G. Marot, M. Rossat, A. Freund, S. Joksch, H. Kawata et al., Cryogenic cooling of monochromators, Review of Scientific Instruments, vol.63, issue.1, pp.477-480, 1992.
DOI : 10.1063/1.1142736

M. Ramanathan, M. Engbretson, and P. A. Montano, A closed loop feedback system for synchrotron radiation double crystal monochromators, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol.266, issue.1-3, pp.471-474, 1988.
DOI : 10.1016/0168-9002(88)90432-9

H. Renevier, S. Grenier, S. Arnaud, J. Berar, B. Caillot et al., Diffraction anomalous fine-structure spectroscopy at beamline BM2 at the European Synchrotron Radiation Facility, Journal of Synchrotron Radiation, vol.10, issue.6, pp.435-444, 2003.
DOI : 10.1107/S0909049503021332

URL : https://hal.archives-ouvertes.fr/hal-00122641

C. S. Rogers and L. Assoufid, Design and thermal stress analysis of high???power x???ray monochromators cooled with liquid nitrogen, Review of Scientific Instruments, vol.66, issue.2, pp.2200-2202, 1995.
DOI : 10.1063/1.1145705

M. W. Ruckman, G. Reisfeld, J. Najeh, M. Weinert, M. Strongin et al., XANES study of hydrogen incorporation in a Pd-capped Nb thin film, Physical Review B, vol.57, issue.7, pp.3881-3886, 1998.
DOI : 10.1103/PhysRevB.57.3881

A. G. Shard, V. R. Dhanak, and A. D. Smith, An electrostrictive drive for fine pitch control in double-crystal monochromators, Journal of Synchrotron Radiation, vol.5, issue.3, pp.829-831, 1998.
DOI : 10.1107/S0909049597014714

D. P. Siddons, Microcontroller-based servo for two-crystal X-ray monochromators, Journal of Synchrotron Radiation, vol.5, issue.3, pp.685-686, 1998.
DOI : 10.1107/S0909049597017111

C. M. Wang, S. Cargill, G. Chan, H. M. Harmer, and M. P. , X-ray Absorption Near-Edge Structure of Grain-Boundary-Segregated Y and Zr in Creep-Resistant Alumina, Journal of the American Ceramic Society, vol.34, issue.10, pp.2492-2498, 2002.
DOI : 10.1111/j.1151-2916.1990.tb05207.x

L. Zhang, W. K. Lee, M. Wulff, and L. Eybert, The performance of a cryogenically cooled monochromator for an in-vacuum undulator beamline, Journal of Synchrotron Radiation, vol.10, issue.4, pp.313-319, 2003.
DOI : 10.1107/S0909049503012135